According to “Standard of water for concrete” you should follow these water quality standards
|
Item |
Prestressed concrete |
Reinforced concrete |
Plain concrete |
|
pH |
≥5.0 |
≥4.5 |
≥4.5 |
|
Insoluble matter |
≤2,000 |
≤2,000 |
≤5,000 |
mg/L |
Insoluble matter |
≤2,000 |
≤5,000 |
≤10,000 |
mg/L |
Cl- |
≤500 |
≤1,000 |
≤3,500 |
mg/L |
SO4 |
≤600 |
≤2,000 |
≤2,700 |
mg/L |
The alkali content |
≤1,500 |
≤1,500 |
≤1,500 |
mg/L |
|
For the design of service life of structural concrete is more than 100 years, chloride ion content
must not exceed 500 mg/L, using steel wire or prestressed concrete of heat-treated steel bar,
chloride ion content must less than 350 mg/L.
Normally, you need consider treating the water for concrete mixing which from underground,
brackish or sea water.